原稿を提出する arrow_forward arrow_forward ..

Measurements of Indoor Radon-222 Concentration inside Iraqi Kurdistan: Case Study in the Summer Season

Abstract

Zakariya A Hussein, Mohamad S Jaafar and Asaad H Ismail

Exposure to natural sources of radiation, especially 222Rn and its short-lived daughter products has become an important issue throughout the world because sustained exposure of humans to indoor radon may cause lung cancer. Therefore, indoor radon concentration levels have been measured inside 8 government hospitals in three main regions (Erbil, Duhok and Sulaymaniya) in Iraqi Kurdistan region during summer season by using CR-39 nuclear track detector. The CR-39 detectors were placed in the all hospitals for three floors (ground, first and second). The highest average radon concentration value and annual effective dose was found to be in the Shaheed Dr. Aso hospital in Sulaymaniya city (52.89 ± 3.52 Bq. m-3 , 1.37 ± 0.09 mSv/y ) respectively and the lowest was found in the Erbil Teaching hospital in Erbil city (30.15 ± 2.85 Bq. m-3 , 0.81 mSv/y) respectively, This depended on the geological formation , type of building material, and the floor level. Therefore, the results showed that the average radon concentration and annual effective dose decreases gradually as the floor level increases The highest and lowest of annual effective dose was found in ground and second floor, respectively. Thus, according to the annual exposure dose data, the workers are safety in most of the hospitals.